Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 253
Filtrar
1.
Cureus ; 16(3): e56415, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38638760

RESUMO

Introduction Anastomotic leakage is a serious complication in colon and rectal cancer surgeries, contributing to increased mortality rates and extended hospital stays. Despite various preventive measures, including intraoperative assessments and transanal drains, the incidence of anastomotic leakage remains a significant concern. This study investigates the potential efficacy of polyglycolic acid (PGA) sheets in reducing anastomotic leakage rates in gastrointestinal surgeries. Materials & methods A retrospective cohort study was conducted between January 2021 and January 2023 at Nagoya Tokushukai General Hospital, Ogaki Tokushukai Hospital, and Haibara General Hospital. A total of 239 patients undergoing colon or rectal cancer surgery were included. Anastomoses were performed with or without PGA sheets, and groups were compared using statistical analyses, including t-tests, Mann-Whitney U tests, and chi-square tests. The primary endpoint was the incidence of anastomotic leakage. Results Of the 239 patients, anastomotic leakage occurred in 14 (6%). The PGA use group (52 patients) showed no instances of anastomotic leakage while the PGA non-use group (187 patients) had 14 cases. Comparisons revealed significant differences in anastomotic leakage rates (p=0.04) between the two groups. Univariate analysis demonstrated a lower incidence of anastomotic leakage associated with PGA use (p=0.04). However, no significant differences were observed for transanal drainage (p=0.66), smoking (p=0.76), steroid use (p=1), and preoperative chemotherapy (p=0.07). Conclusion This study suggests that the use of PGA sheets in gastrointestinal anastomosis may contribute to a lower incidence of anastomotic leakage. The findings highlight the need for further prospective studies with a larger sample size, distinguishing between colon and rectum surgeries. Despite the limitations of this retrospective study, the observed reduction in anastomotic leakage frequency with PGA sheet use is noteworthy, emphasizing the potential significance of this approach in preventing a critical complication in colorectal surgeries.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38601270

RESUMO

We describe the case of a 66-year-old man with an anastomotic fistula after rectal surgery, which was treated colonoscopically using polyglycolic acid sheets and fibrin glue. Polyglycolic acid sheets and fibrin glue have been used in thoracic surgery and otolaryngology to reinforce sutures and prevent air leakage. There have been recent reports of their use in endoscopic surgery for the closure of intraoperative perforations after endoscopic submucosal dissection and for fistula closure after upper gastrointestinal tract surgery. However, anastomotic fistulas in colorectal surgery are difficult to visualize endoscopically and may be difficult to suture with clips due to fibrosis. Polyglycolic acid sheets can be easily trimmed, and the fistula can be easily filled using these sheets; moreover, using fibrin glue to fix the sheets may enable fistula closure in areas that are difficult to visualize endoscopically.

3.
J Gastric Cancer ; 24(2): 220-230, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38575514

RESUMO

PURPOSE: Prevention of pancreas-related complications after gastric cancer surgery is critical. Polyglycolic acid (PGA) mesh reduces postoperative pancreatic fistula formation following pancreatic resection. However, the clinical efficacy of PGA mesh in gastric cancer surgery has not been adequately investigated. MATERIALS AND METHODS: This retrospective study compared the short-term outcomes between two groups: patients who underwent minimally invasive R0 gastrectomy for gastric cancer with the use of a PGA mesh (PGA group) and those without the use of a PGA mesh (non-PGA group) at the Cancer Institute Hospital, Tokyo, between January 2019 and May 2023. Propensity score matching (PSM) was performed to adjust for the possible confounding factors. RESULTS: A total of 834 patients were initially included, of whom 614 (307 in each group) remained after PSM. The amylase levels in the drained abdominal fluid on postoperative days 1 and 3 were similar between the PGA and non-PGA groups. The PGA group had a significantly lower incidence of pancreas-related complications of Clavien-Dindo grade ≥2 than that in the non-PGA group (6.8% vs. 2.9%, P=0.025). In subgroup analyses, the odds ratio for pancreas-related complications appeared to be better in the PGA group than in the non-PGA group in patients with American Society of Anesthesiologists Physical Status Classification score of 2 or 3, those operated via a laparoscopic approach, and those undergoing procedures other than proximal gastrectomy. CONCLUSIONS: The use of PGA mesh significantly reduced pancreas-related complications after minimally invasive surgery for gastric cancer and might thus benefit patients at risk of such complications.

4.
J Cardiothorac Surg ; 19(1): 149, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38515189

RESUMO

OBJECTIVE: Our previous study revealed that the viscosity of fibrinogen could influence the effectiveness of ventilation and anchoring (V/A) methods for controlling air leakages. Here, we examined the association between the viscosity of fibrinogen and effectiveness using an ex vivo pig model. METHODS: The fibrin glue used in this study was BOLHEAL® (KM Biologics Co., Ltd., Kumamoto, Japan). We prepared three types of fibrinogen with different viscosities (higher and lower than normal), including one without additives. Using an ex vivo pig model, a pleural defect was made, and the defect was repaired using three different viscosities of fibrinogen through the V/A method. We measured the rupture pressure at the repair site (N = 10) and histologically evaluated the depth of fibrin infiltration into the lung parenchyma at the repair sites. RESULTS: The median rupture pressure was 51.5 (40-73) cmH2O in Group 1 (lower viscosity), 47.0 (47-88) cmH2O in Group 2 (no change in viscosity), and 35.5 (25-61) cmH2O in Group 3 (higher viscosity). There was no statistically significant difference between Groups 1 and 2 (p = 0.819), but the rupture pressure was significantly higher in Group 2 than in Group 3 (p = 0.0136). Histological evaluation revealed deep infiltration of fibrin into the lung parenchyma in Groups 1 and 2, but no such infiltration was observed in the higher-viscosity group. CONCLUSIONS: The results of this experiment suggested that the V/A method using fibrin glue containing low-viscosity fibrinogen was more effective in controlling air leakage due to pleural defects.


Assuntos
Adesivo Tecidual de Fibrina , Hemostáticos , Animais , Suínos , Adesivo Tecidual de Fibrina/farmacologia , Adesivo Tecidual de Fibrina/uso terapêutico , Viscosidade , Fibrinogênio/uso terapêutico , Pulmão/patologia
5.
J Thorac Dis ; 16(2): 893-900, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38505053

RESUMO

Background: Currently, it is unknown whether polyglycolic acid (PGA) felt staplers can reduce the occurrence of intraoperative air leaks. We investigated whether staplers with bioabsorbable PGA felt reduced intraoperative air leakage compared to the conventional stapler in patients undergoing lung resection. Methods: From 2013 to 2021, 211 patients diagnosed with lung cancer or pulmonary metastasis underwent lung resection using only PGA felt (n=88) or conventional (n=123) staplers at Tokyo Rosai Hospital. One-to-one propensity score matching was used to compare intraoperative air leak rates, operation time, and intraoperative bleeding between the two groups. Results: The PGA felt group required more staples than the conventional stapler group. The forced expiratory volume in one second percentage of predicted in the PGA felt stapler group was lower than that in the conventional stapler group. In the PGA felt stapler group, 56.8% of patients had undergone anatomic lung resection, whereas 29.3% of patients in the conventional stapler group had undergone wedge resection. In a propensity-matched analysis of 67 pairs, the occurrence of intraoperative air leaks was significantly lower in the PGA felt stapler group than in the conventional stapler group (16.4% vs. 56.7%, P<0.001). The operation time was significantly shorter and intraoperative bleeding was significantly lower in the PGA felt stapler group than in the conventional stapler group (P=0.001 and P=0.016, respectively). Conclusions: Pulmonary resection using staplers with a PGA felt could reduce the occurrence of intraoperative air leaks among patients undergoing lung resection.

6.
World J Gastrointest Endosc ; 16(1): 1-4, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38313459

RESUMO

Esophageal cancer is the seventh most common type of cancer and the sixth leading cause of cancer -related mortality worldwide. Endoscopic submucosal dissection (ESD) is widely used for the resection of early esophageal cancer. However, post-ESD esophageal stricture is a common long-term complication, which requires attention. Patients with post-ESD esophageal stricture often experience dysphagia and require multiple dilatations, which greatly affects their quality of life and increases healthcare costs. Therefore, to manage post-ESD esophageal stricture, researchers are actively exploring various strategies, such as pharmaceutical interventions, endoscopic balloon dilation, and esophageal stenting. Although steroids-based therapy has achieved some success, steroids can lead to complications such as osteoporosis and infection. Meanwhile, endoscopic balloon dilatation is effective in the short term, but is prone to recurrence and perforation. Additionally, esophageal stenting can alleviate the stricture, but is associated with discomfort during stenting and the complication of easy displacement also present challenges. Tissue engineering has evolved rapidly in recent years, and hydrogel materials have good biodegradability and biocompatibility. A novel type of polyglycolic acid (PGA) sheets has been found to be effective in preventing esophageal stricture after ESD, with the advantages of a simple operation and low complication rate. PGA membranes act as a biophysical barrier to cover the wound as well as facilitate the delivery of medications to promote wound repair and healing. However, there is still a lack of multicenter, large-sample randomized controlled clinical studies focused on the treatment of post-ESD esophageal strictures with PGA membrane, which will be a promising direction for future advancements in this field.

7.
Colorectal Dis ; 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321510

RESUMO

Carbon ion radiotherapy (CIRT) has received attention for the treatment of locally recurrent rectal cancer. When the surrounding primary organs are close to the irradiation site, a spacer is required to ensure safe irradiation. This work describes a novel technique using a bioabsorbable polyglycolic acid spacer placed laparoscopically and presents a technical report with five case studies. The short-term surgical outcomes were as follows: mean operating time 235 min with blood loss of 38 mL. CIRT was planned, and the patients underwent irradiation within 2 months of surgery. No pelvic infections occurred, and all procedures were performed safely. Herein, were present a technical report with reference to a video of the surgical procedure.

8.
Polymers (Basel) ; 16(2)2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38256980

RESUMO

In this research, fully degradable elastomeric sealing materials were developed to enhance the environmental sustainability of oil and gas extraction. The modification of millable polyurethane rubber (MPU) with polyglycolic acid/hydrogenated nitrile butadiene rubber (PGA/HNBR) led to the synthesis of PGA@MPU/HNBR composite materials. The impact of varying monomer quantities on the mechanical properties, degradation behavior, degradation mechanisms, and thermal stability of these materials was investigated. Our findings illustrate that an increasing proportion of HNBR in the PGA@MPU/HNBR composite materials resulted in a decreased degradation rate. Simultaneously, higher HNBR content improved the thermal stability of the materials, while the inclusion of PGA reduced material hardness, rendering the composites more susceptible to swelling. At an HNBR content of 40 phr, MPU at 60 phr, and PGA at 6 phr, the composite material demonstrated the highest retention of mechanical properties at 31.3% following 168 h of hydrolysis at 100 °C. The degradation of the composite materials in 100 °C water primarily resulted from the hydrolysis of MPU's ester groups, with HNBR remaining unaffected.

10.
Auris Nasus Larynx ; 51(2): 301-304, 2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-37985345

RESUMO

Oropharyngeal cancer requiring combined resection of the soft palate is relatively out of indication for transoral robotic surgery (TORS) due to postoperative functional problems. We report the case of a patient with oropharyngeal cancer in which half of the soft palate was resected, and good function was maintained using the Gehanno method, polyglycolic acid (PGA) sheet and fibrin glue. The patient was a woman in her 50 s with oropharyngeal squamous cell carcinoma (p16-positive, T2N1M0 stage I). TORS and right neck dissection were performed the same day. About half of the soft palate was resected cranially. After closing the right nasopharynx with the Gehanno method, the sutured part was reinforced by covering with a PGA sheet of about 10 mm on a side and fibrin glue. Oral feeding was started on postoperative day 4, but no nasal reflux was observed. Three weeks postoperatively, no nasal reflux was evident, normal food intake was possible, and nasal breathing was maintained. This technique may be effective after TORS surgery that requires soft palate resection.

11.
Ophthalmic Res ; 66(1): 1148-1158, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37690450

RESUMO

INTRODUCTION: Dry eye disease (DED) is a multifactor-induced disease accompanied by increased osmolarity of the tear film and inflammation of the ocular surface. Traditional anti-inflammation agent corticosteroids applied in DED treatment could result in high intraocular pressure, especially in long-term treatment. Therefore, we explored a nano drug that aimed to block the formation pathway of DED which had anti-inflammatory, sustained release, and good biocompatibility characteristics in this study. METHODS: We prepared a novel nanomedicine (Tet-ATS@PLGA) by the thin film dispersion-hydration ultrasonic method and detected its nanostructure, particle size, and zeta potential. Flow cytometry was used to detect the cell survival rate of each group after 24 h of drug treatment on inflammed Statens Seruminstitut Rabbit Corneal (SIRC) cells. Observed and recorded corneal epithelial staining, tear film rupture time, and Schirmer test to detect tear secretion on the ocular surface of rabbits. The corneal epithelial thickness, morphology, and number of bulbar conjunctival goblet cells were recorded by H&E staining. Finally, we detected the expression of VEGF, IL-1ß, PGE2, and TNF-α by cellular immunofluorescence staining and enzyme-linked immunosorbent assay (ELISA). RESULTS: The encapsulation efficiency and drug loading of Tet-ATS@PLGA were 79.85% and 32.47%, respectively. At eye surface temperature, Tet can easily release from Tet-ATS@PLGA while that it was difficult to release at storage temperature and room temperature. After 2 weeks medication, Tet-ATS@PLGA can effectively improve the tear film rupture time and tear secretion time in a DED model (p <0.05). Compared with the normal group (62.34 ± 4.86 mm), the thickness of corneal epithelium in ATS (29.47 ± 3.21 mm), Tet-ATS (46.23 ± 2.87 mm), and Tet-ATS@PLGA (55.76 ± 3.95 mm) gradually increased. Furthermore, the flow cytometry indicated that Tet-ATS@PLGA can effectively promote the apoptosis of inflammatory SIRC cells, and the cellular immunofluorescence and ELISA experiments showed that the expression intensity of inflammatory factors such as VEGF, IL-1ß, PGE2, and TNF-α decreased in this process. Interestingly, Tet also had the effect of reducing intraocular pressure. CONCLUSION: Tet-ATS@PLGA can effectively promote the apoptosis of inflammatory corneal epithelial cells, thus inhibiting the expression of inflammatory factors to block the formation of DED and improve the secretion of tear on the ocular surface.


Assuntos
Síndromes do Olho Seco , Nanopartículas , Animais , Coelhos , Ácido Poliglicólico/análise , Ácido Poliglicólico/metabolismo , Ácido Poliglicólico/uso terapêutico , Fator de Necrose Tumoral alfa , Dinoprostona/análise , Dinoprostona/metabolismo , Dinoprostona/uso terapêutico , Fator A de Crescimento do Endotélio Vascular/metabolismo , Síndromes do Olho Seco/diagnóstico , Lágrimas/metabolismo , Córnea/metabolismo , Anti-Inflamatórios/uso terapêutico , Nanopartículas/química
12.
Photodiagnosis Photodyn Ther ; 44: 103752, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37595657

RESUMO

AIM: The objective of the current study was to compare the effectiveness of antimicrobial photodynamic therapy (PDT) versus Poly-L-glycolic acid nanoparticles loaded riboflavin incorporated in aloe vera gel (PGA/RF/AV) on periimplant parameters and bacterial counts in chronic hyperglycemic patients having periimplantitis. METHODS: One hundred and two diabetic patients undergoing mechanical debridement (MD) were equally divided into three groups: Group 1: PGA/RF/AV+ MD, Group 2: PDT + MD, and Group 3: MD alone. Periimplant parameters [Bleeding on probing (BoP), probing depth (PD), plaque index (PI), marginal bone level (MBL)] were recorded in all three groups. Periimplant plaque samples were studied to record the levels of Tannerella forsythia (Tf) and Porphyromonas gingivalis (Pg). The recordings were taken at baseline, 3 months and 6 months post treatment. RESULTS: All three groups showed a reduction in severity of periimplantitis measured in terms of PD, PI, MBL and BoP. A statistically significant reduction in PD, PI and MBL was found in patients in Group 2 whereas participants of Group 1 were found to have a significant decrease in BoP. A statistically significant decline in the numbers of both the bacterial species was seen in Group 2 at the three-month follow-up whereas at the six-month follow-up, a statistically significant reduction was observed in treatment Group 2 in the levels of Tf species only. CONCLUSION: Riboflavin-loaded nanocarrier incorporated in aloe vera gel showed greater clinical efficacy than PDT alone in the treatment of periimplantitis in chronic hyperglycemic individuals.


Assuntos
Aloe , Peri-Implantite , Fotoquimioterapia , Humanos , Peri-Implantite/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Desbridamento , Riboflavina/uso terapêutico
13.
Cureus ; 15(7): e42348, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37621806

RESUMO

INTRODUCTION: Episiotomy, the deliberate surgical incision on the vaginal orifice during vaginal delivery, requires prompt repairing of the incised tissue. It may be associated with bleeding, infection, dehiscence, dyspareunia, short-term pain, and prolonged hospital stay. The outcome of surgery depends on the suture material and technique to repair the episiotomy. OBJECTIVE: We aim to subjectively assess perineal pain and maternal morbidity following episiotomy repair with Truglyde Fast® (Healthium Medtech Limited, Bengaluru, India) and Safil Quick® (B. Braun Medical Private Limited, Mumbai, India) polyglycolic acid fast-absorbing suture. MATERIALS AND METHODS: This multicentric, prospective, randomized (1:1), two-arm, parallel-group, single-blind study was started in August 2020 and completed in March 2021. Ninety-nine primiparous or multiparous eligible women requiring episiotomy were recruited to Truglyde Fast® (n=51) and Safil Quick® (n=48) groups. The primary outcome measure was post-episiotomy perineal pain to be assessed using a visual analog scale (VAS). Secondary endpoints included evaluation of local anesthesia (quantity), intraoperative suture handling, number of sutures utilized, time spent for episiotomy repair and complete healing, analgesic number and dosage, early and late wound complications, presence of residual suture and frequency of re-suturing, resumption of sexual activity and dyspareunia, and adverse events. The threshold to discriminate significant from non-significant outcomes was p<0.05. RESULTS: At all visits, a non-significant change in perineal pain was noted between Truglyde Fast® and Safil Quick® groups. A significant difference (p<0.05) in the number of sutures used and intraoperative handling characteristics was observed between thegroups. Results of other secondary endpoints showed non-significant differences. CONCLUSION: Truglyde Fast® and Safil Quick® polyglycolic acid fast-absorbing sutures are clinically equivalent. Both sutures are safe and effective for episiotomy repair following vaginal delivery with minimal perineal pain and risk of maternal morbidity.

14.
J Gastroenterol ; 58(11): 1094-1104, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37635203

RESUMO

BACKGROUND: Endoscopic submucosal dissection (ESD) has been the first-line treatment for early-stage esophageal cancer. However, it often causes postoperative stricture in cases requiring wide dissection. Basic fibroblast growth factor (bFGF) reportedly has anti-scarring effects during cutaneous wound healing. We hypothesized that suppressing myofibroblast activation will prevent stricture after esophageal ESD. METHODS: We resected a complete porcine esophagus circumference section by ESD. To investigate the preventive effect of bFGF on esophageal stricture formation after ESD, we endoscopically applied bFGF-soaked poly-glycolic acid (PGA) sheets onto the wound bed after ESD and fixed them by spraying fibrin glue (PGA + bFGF group), PGA sheets alone onto the wound bed and fixed them by spraying fibrin glue (PGA group), or nothing (control group). After removing the esophagus on day 22, we evaluated the mucosal constriction rate. RESULTS: Compared with those in the control group, esophageal stricture was significantly reduced in the PGA + bFGF group, and the areas stained with α-SMA and calponin-1 antibodies were significantly inhibited in the PGA + bFGF and PGA groups. The thickness of the fibrous layer in the PGA + bFGF group was uniform compared to that of the other groups. Thus, PGA + bFGF inhibited the development of unregulated fibroblasts in the acute phase, leading to uniform wound healing. CONCLUSIONS: Stenosis after esophageal ESD is related to fibrosis in the acute phase. Administration of PGA and bFGF suppresses myofibroblast activation in the acute phase, thereby preventing esophageal constriction in pigs.

15.
J Adv Periodontol Implant Dent ; 15(1): 28-34, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37645553

RESUMO

Background: Polylactic-co-glycolic acid and zinc oxide (PLGA-ZnO) nanocomposite has been investigated for its antibacterial properties, which could be beneficial for adding to wound dressings after periodontal surgery. However, its cytotoxicity against human gingival fibroblasts (HGFs) remains unclear and should be evaluated. Methods: ZnO nanoparticles were synthesized using the hydrothermal method. These metallic nanoparticles were incorporated into the PLGA matrix by the solvent/non-solvent process. The nanomaterial was evaluated by field emission scanning electron microscopy (FESEM), Fourier transform infrared (FTIR), thermogravimetric analysis (TGA), and x-ray diffraction (XRD) analyses. HGF cells were acquired from the National Cell Bank and categorized into four groups: ZnO, PLGA, ZnO-PLGA, and control. The cells were exposed to different ZnO (1, 20, 40, 60, 80, and 100 µg/mL) and PLGA (0.2, 4, 8, 12, 16, and 20 µg/mL) concentrations for 24 and 48 hours. The cytotoxicity was tested using the MTT assay. The data were analyzed using SPSS 25, and P<0.05 was considered statistically significant. Results: ZnO nanoparticles exhibited significant toxicity at≥40 µg/mL concentrations after 24 hours. Cell viability decreased significantly at all the tested concentrations after 48 hours of exposure. PLGA-ZnO cell viability in 24 hours was similar to the control group for all the concentrations up to 80 µg/mL. Conclusion: ZnO nanoparticles could be toxic against HGF in high concentrations and with prolonged exposure. Therefore, incorporating ZnO nanoparticles into a biocompatible polymer such as PLGA could be a beneficial strategy for reducing their toxicity.

16.
Cartilage ; : 19476035231193087, 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37632127

RESUMO

OBJECTIVE: Meniscal tears treated with a partial meniscectomy could induce knee osteoarthritis, thereby altering or damaging knee kinetics and biomechanics. We have developed a meniscal scaffold made of polyglycolic acid (PGA) coated with polylactic acid/caprolactone (PGA scaffold), which could induce new tissue growth of meniscus-like tissue. This study aimed to evaluate the safety and efficacy of a novel meniscal scaffold for the treatment of irreparable meniscal injuries. DESIGN: This study describes the findings of a cyclic torque test and first clinical trial of a PGA scaffold for inducing meniscus-like tissue in humans. As the first step, biomechanical testing of the PGA scaffold was performed using a cyclic torque test. Six patients underwent arthroscopic implantation of the PGA scaffold. Furthermore, the patients underwent preoperative clinical, serological, radiographic, and magnetic resonance imaging examinations at 3, 6, and 12 months postoperatively. The patients also underwent a second-look arthroscopy 12 months after implantation. RESULTS: Torque increased with increasing cyclic loading. However, no structural damage to the sample was noted after 70,000 loading cycles. All patients showed improvement in pain, Lysholm scores, Tegner activity scores, International Knee Documentation Committee, and knee injury and osteoarthritis outcome. The second-look arthroscopy revealed that meniscal tissue had regenerated in 5 patients (83%). Radiography and magnetic resonance imaging confirmed no progression of degenerative joint disease. CONCLUSIONS: The PGA scaffold could tolerate shear forces, did not produce safety concerns, and may have therapeutic potentials for irreparable meniscal tears in humans.

17.
Clin Exp Gastroenterol ; 16: 169-172, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37614978

RESUMO

Pancreatic fistula after gastrectomy with lymph node dissection is associated with prolonged hospital stay and critical complications such as intra-abdominal bleeding and sepsis. Polyglycolic acid (PGA) sheets are absorbable suture reinforcement materials. A randomized Phase II trial has been planned to evaluate the effect of PGA sheets on preventing postoperative pancreatic fistula. A total of 320 patients will be recruited from thirteen institutions. Patients who are scheduled to undergo distal or total gastrectomy will be randomly allocated into the PGA group or control group, and the dissected area around the pancreas will be covered by the PGA sheet in the PGA group. The primary endpoint will be the maximum value of drain amylase concentration up to 5 days after surgery. The secondary endpoints will be as follows: transition of value of amylases of drain discharge, incidence of pancreatic fistula, incidence of intra-abdominal abscess, white blood cell count, value of C-reactive protein, incidence of postoperative complication, duration of antibiotic agents administration, duration of abdominal drainage, usage of octreotide, duration of hospital stay, incidence of bleeding in abdominal cavity, mortality, and incidence of reoperation.

18.
J Thorac Dis ; 15(7): 3783-3790, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37559612

RESUMO

Background: Video-assisted thoracoscopic surgery (VATS) is a standard primary spontaneous pneumothorax (PSP) procedure. However, its high recurrence rate compared to open thoracotomy is a problem. Therefore, various methods to prevent recurrence have been developed. The present study investigated the risk factors for postoperative recurrence of PSP after VATS. Methods: From January 2008 to November 2022, 207 patients younger than 40 years of age without underlying pulmonary disease underwent thoracoscopic bullectomy for PSP. Among them, 96 underwent staple line reinforcement with a polyglycolic acid (PGA) sheet and autologous blood spraying. Patient characteristics and surgical outcomes were analyzed to determine the prognostic factors for postoperative recurrence. Results: Twenty-seven patients (13.0%) experienced recurrences. A multivariate analysis using Cox regression analysis revealed that age younger than 20 years [P=0.039; hazard ratio (HR) =2.337; 95% confidence interval (CI): 3.283-17.287], history of contralateral pneumothorax (P<0.001; HR =7.533; 95% CI, 1.486-12.336), and no staple line reinforcement (P=0.007; HR =4.282; 95% CI, 1.043-5.236) were risk factors for recurrence after pneumothorax surgery. Conclusions: Age younger than 20 years and history of contralateral pneumothorax were risk factors for postoperative recurrence of pneumothorax. Staple line reinforcement with a PGA sheet and spraying of autologous blood reduced the postoperative recurrence rate of PSP.

19.
Polymers (Basel) ; 15(13)2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37447410

RESUMO

This study investigated the impact of a multiple epoxy chain extender (ADR) on the rheological behavior, crystallization, and mechanical properties of polyglycolic acid (PGA). Tests of the torque and melt mass flow rate and dynamic rheological analysis were conducted to study the rheological behavior of PGA modified with ADR. The rheological results of the modified PGA showed a significantly increased viscosity and storage modulus with an increase in the ADR amount, which could be attributed to the chain extension/branching reactions between PGA and ADR. It was proved that ADR could be used as an efficient chain extender for tailoring the rheological performance of PGA. The Han plot of the modified PGA showed a transition of viscous behavior to elastic behavior, while the ADR content was increased from 0 to 0.9 phr. The formation of long-chain branches (LCBs) was confirmed via the Cole-Cole plot and weighted relaxation spectrum, wherein the LCBs substantially changed the rheological behavior of the modified PGA. The vGP plots predicted a star-type topological structure for the LCBs. The results of non-isothermal crystallization kinetics suggested that the crystallization of the modified PGA was predominantly homogeneous nucleation and three-dimensional growth. The crystallinity decreased slightly with the increase in the ADR amount. Compared to neat PGA, the modified PGA samples exhibited better tensile and flexural performances.

20.
J Funct Biomater ; 14(7)2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37504832

RESUMO

This retrospective study compared the effectiveness of different materials used in Uvulopalatopharyngoplasty (UPPP) for snoring or obstructive sleep apnea treatment, focusing on the impact on bleeding control, pain control, and healing ability. The study population comprised 213 patients who underwent UPPP at Wan-Fang Hospital between July 2018 and October 2022 divided into four groups based on the postoperative material used: No Material Use Group, Tissue Glue Group, Platelet-Rich Plasma (PRP) Group, and Polyglycolic Acid (PGA) Sheet Group. Results showed significant differences in operation time and intraoperative bleeding amount among the groups, with the Tissue Glue Group demonstrating the shortest operation time. While no significant differences in postoperative pain at 24 h were observed, PRP and PGA Sheet groups exhibited lower average pain scores in cases with higher pain levels. Postoperative complications and emergency room visits due to pain or bleeding varied among the groups, with the No Material Use Group having the highest incidence, although no statistical significance was achieved. This study provides insights into the potential benefits of using advanced materials in UPPP, guiding future research and clinical practice to improve patient care and outcomes.

SELEÇÃO DE REFERÊNCIAS